A Startling Fact about Iontophoresis Uncovered

According to the suffering and the health of a patient, device selection often performs a decisive function in the feasible therapeutic achievement. With appropriate apparatus selection you have a very big probability of success with an iontophoresis device to dry. Not necessarily with treatment strictly relating to manual a success (independence from sweat) is usually reached. In cases like this, we are of program and especially after the purchase of program – with our experience since 1999 in the field of iontophoresis – to the side. With the technique Iontophoresis, many manage to “get dry”.

really great feeling when hands / foot / armpits are dried out and warm rather than wet and chilly (frog hands). Still, many users delivered their iontophoresis machine back – why? We also asked ourselves this query, most importantly because we are also interested in providing our clients with optimum and effective therapy.

Background information: There are two types of treatment streams: Pulse and DC. DC products deliver the effect of greater performance (sweat level of resistance) with the same current environment. Today you could arrive to the final outcome: All right, I’m sweating greatly, so DC is way better for me personally, and cheaper it really is! Unfortunately this is simply not always correct: the therapy with pulse current products is merely more pleasurable with the same current environment. Consequently, with a pulse-current gadget, you could drive higher currents compared to the direct current, because the current is better tolerated.

Nevertheless, the limit ideals ​​must not end up being exceeded (Dr. Hoenle specifies a maximum of 25 mA for your feet, 15 mA for the hands and 5 mA for the treatment of the underarms as a limit). These values ​​are not normally achieved with direct current devices, unless the patient is totally insensitive to the procedure stream, which is quite rare, nevertheless, and your skin must join the whole. Even on your toes, 30 mA DC is a word! When you can established 5 mA with a pulse power device under the armpits, this might be more than enough to record a success because the skin there is quite thin (and sadly sensitive) and for that reason does not need higher currents. Specifically with the armpits, DC devices will often tolerate just 1mA and thus in some instances no therapeutic achievement may be accomplished. The same applies to the hands, where you frequently have minor injuries (nail, etc.) where not only direct currents can be very painful. It isn’t so much the topic of your feet, but also the guideline of the term: The pulse current is certainly often a lot more pleasant there as well.

Leave a Reply

Your email address will not be published. Required fields are marked *